Installation and testing of an optimized epithermal neutron beam at the Brookhaven Medical Research Reactor (BMRR)
Conference
·
OSTI ID:5597308
- Brookhaven National Lab., Upton, NY (USA)
Various calculations indicate that an optimized epithermal neutron beam can be produced by moderating fission neutrons either with a combination of Al and D{sub 2}O, or with Al{sub 2}O{sub 3}. We have designed, installed and tested an Al{sub 2}O{sub 3} moderated epithermal neutron beam at the Brookhaven Medical Research Reactor (BMRR). The epithermal neutron fluence rate of 1.8 {times} 10{sup 9} n/cm{sup 2}-sec produces a peak thermal neutron fluence rate of 1.9 to 2.8 {times} 10{sup 9} n/cm{sup 2}-sec in a tissue equivalent (TE) phantom head, depending on the configuration. Thus a single therapy treatment of 5 {times} 10{sup 12} n/cm{sup 2} can be delivered in 30--45 minutes. All irradiation times are given for a BMRR power of 3 MW, which is the highest power which can be delivered continuously. 18 refs., 8 figs., 4 tabs.
- Research Organization:
- Brookhaven National Lab., Upton, NY (USA)
- Sponsoring Organization:
- DOE/ER
- DOE Contract Number:
- AC02-76CH00016
- OSTI ID:
- 5597308
- Report Number(s):
- BNL-43102; CONF-8903150--2; ON: DE89017606
- Country of Publication:
- United States
- Language:
- English
Similar Records
Upgrades of the epithermal neutron beam at the Brookhaven Medical Research Reactor
Epithermal beam development at the BMRR (Brookhaven Medical Research Reactor): Dosimetric evaluation
Comparison of measured parameters from a 24--keV and a broad spectrum epithermal neutron beam for neutron capture therapy: An identification of consequential parameters
Conference
·
Fri Dec 30 23:00:00 EST 1994
·
OSTI ID:392714
Epithermal beam development at the BMRR (Brookhaven Medical Research Reactor): Dosimetric evaluation
Conference
·
Thu Aug 24 00:00:00 EDT 1989
·
OSTI ID:5473833
Comparison of measured parameters from a 24--keV and a broad spectrum epithermal neutron beam for neutron capture therapy: An identification of consequential parameters
Journal Article
·
Wed Oct 31 23:00:00 EST 1990
· Medical Physics; (USA)
·
OSTI ID:5984205
Related Subjects
550603* -- Medicine-- External Radiation in Therapy-- (1980-)
62 RADIOLOGY AND NUCLEAR MEDICINE
BEAMS
BIOLOGICAL LOCALIZATION
BODY
BORON COMPOUNDS
DISEASES
DISTRIBUTION
DOSES
DRUGS
INSTALLATION
LABELLED COMPOUNDS
MEDICINE
NEOPLASMS
NEUTRON BEAMS
NEUTRON CAPTURE THERAPY
NEUTRON THERAPY
NUCLEAR MEDICINE
NUCLEON BEAMS
OPTIMIZATION
PARTICLE BEAMS
RADIATION DOSES
RADIOLOGY
RADIOPHARMACEUTICALS
RADIOTHERAPY
TESTING
THERAPY
TISSUE DISTRIBUTION
TISSUES
62 RADIOLOGY AND NUCLEAR MEDICINE
BEAMS
BIOLOGICAL LOCALIZATION
BODY
BORON COMPOUNDS
DISEASES
DISTRIBUTION
DOSES
DRUGS
INSTALLATION
LABELLED COMPOUNDS
MEDICINE
NEOPLASMS
NEUTRON BEAMS
NEUTRON CAPTURE THERAPY
NEUTRON THERAPY
NUCLEAR MEDICINE
NUCLEON BEAMS
OPTIMIZATION
PARTICLE BEAMS
RADIATION DOSES
RADIOLOGY
RADIOPHARMACEUTICALS
RADIOTHERAPY
TESTING
THERAPY
TISSUE DISTRIBUTION
TISSUES