Technique to increase the H/sup +/ ion fraction in a multicusp source
Journal Article
·
· Rev. Sci. Instrum.; (United States)
It is possible to filter out the primary ionizing electrons from the ion extraction region of a multicusp source by installing the filament inside the dipole fields of the permanent magnets and thereby enhance the H/sup +/ ion species in the extracted beam. An optimum position of the filament has been determined such that a quiescent plasma together with a uniform plasma density profile across the extraction plane can be obtained.
- Research Organization:
- Lawrence Berkeley Laboratory, University of California, Berkeley, California 94720
- DOE Contract Number:
- AC03-76SF00098
- OSTI ID:
- 5592177
- Journal Information:
- Rev. Sci. Instrum.; (United States), Journal Name: Rev. Sci. Instrum.; (United States) Vol. 54:10; ISSN RSINA
- Country of Publication:
- United States
- Language:
- English
Similar Records
Extraction of volume-produced H/sup -/ ions from a multicusp source
Production of low axial energy spread ion beams with multicusp sources
Beam emittance measurements on multicusp ion sources
Journal Article
·
Fri Dec 31 23:00:00 EST 1982
· Rev. Sci. Instrum.; (United States)
·
OSTI ID:6650152
Production of low axial energy spread ion beams with multicusp sources
Thesis/Dissertation
·
Fri May 01 00:00:00 EDT 1998
·
OSTI ID:674707
Beam emittance measurements on multicusp ion sources
Conference
·
Tue Aug 01 00:00:00 EDT 1995
·
OSTI ID:382975