HVAC instrument system for gas-insulated coaxial lines. Final report
Technical Report
·
OSTI ID:5591266
This program was conducted for the development of metering quality, 0.3% accuracy class, current, and voltage instrumentation for an advanced 1200 kV, as gas-insulated power transmission system. This instrumentation is designed and uniquely adapted to the geometry of the coaxial line. The physical objective of the program is a test section of 1200 kV coaxial gas bus containing prototype instruments for measuring line current (1 per unit = 3000 A, 60 Hz), line voltage (1 per unit = 693 kV, 60 Hz line-to-ground) and for injecting and receiving carrier power (about 10W) at frequencies typically in the 100 kHz to 500 kHz range. In addition to a metering specification, current and voltage instrumentation must respond to transient conditions with sufficient bandwidth (about 5 kHz) for use in protective relaying or measuring fault transients. The design fabrication and testing of the measuring instruments and associated electronic equipment for signal amplification are described. Test results indicate the system will meet the requirements of both revenue metering, 0.3% class, and protective relaying. Outputs of the signal amplifier channels are typically 3 to 5 V rms at normal line power and are suitable for metering or driving static relays and other low-load-burden (2000 ..cap omega..) devices. Initial field tests are planned at the EPRI Waltz Mill Cable Testing Facility, near Pittsburgh, PA.
- Research Organization:
- General Electric Co., Schenectady, NY (USA). Corporate Research and Development Dept.
- DOE Contract Number:
- AC01-76ET29661
- OSTI ID:
- 5591266
- Report Number(s):
- DOE/ET/29661-1; ON: DE82007061
- Country of Publication:
- United States
- Language:
- English
Similar Records
Variable frequency response testbed to validate protective relays up to 20 kHz☆
Application of block pulse functions in a polyphase digital distance relay
Oak Ridge National Laboratory Current Magnitude and Frequency Response of SIPROTEC Relays
Journal Article
·
Tue Jun 01 20:00:00 EDT 2021
· Electric Power Systems Research
·
OSTI ID:1766424
Application of block pulse functions in a polyphase digital distance relay
Conference
·
Sat Dec 30 23:00:00 EST 1995
·
OSTI ID:415570
Oak Ridge National Laboratory Current Magnitude and Frequency Response of SIPROTEC Relays
Technical Report
·
Mon Jun 01 00:00:00 EDT 2020
·
OSTI ID:1649417
Related Subjects
200301* -- Power Transmission & Distribution-- AC Systems
EHV & UHV-- (-1989)
24 POWER TRANSMISSION AND DISTRIBUTION
440300 -- Miscellaneous Instruments-- (-1989)
47 OTHER INSTRUMENTATION
AC SYSTEMS
CABLES
CONDUCTOR DEVICES
CURRENTS
DATA
DESIGN
ELECTRIC CABLES
ELECTRIC CURRENTS
ELECTRIC MEASURING INSTRUMENTS
ELECTRIC POTENTIAL
ELECTRICAL EQUIPMENT
ELECTRONIC EQUIPMENT
ENERGY SYSTEMS
EQUIPMENT
EXPERIMENTAL DATA
FLUORIDES
FLUORINE COMPOUNDS
GAS-INSULATED CABLES
HALIDES
HALOGEN COMPOUNDS
INFORMATION
MEASURING INSTRUMENTS
NUMERICAL DATA
PERFORMANCE
POWER SUBSTATIONS
POWER SYSTEMS
POWER TRANSMISSION LINES
SULFUR COMPOUNDS
SULFUR FLUORIDES
TRANSFORMERS
TRANSIENTS
UHV AC SYSTEMS
VOLTAGE REGULATORS
EHV & UHV-- (-1989)
24 POWER TRANSMISSION AND DISTRIBUTION
440300 -- Miscellaneous Instruments-- (-1989)
47 OTHER INSTRUMENTATION
AC SYSTEMS
CABLES
CONDUCTOR DEVICES
CURRENTS
DATA
DESIGN
ELECTRIC CABLES
ELECTRIC CURRENTS
ELECTRIC MEASURING INSTRUMENTS
ELECTRIC POTENTIAL
ELECTRICAL EQUIPMENT
ELECTRONIC EQUIPMENT
ENERGY SYSTEMS
EQUIPMENT
EXPERIMENTAL DATA
FLUORIDES
FLUORINE COMPOUNDS
GAS-INSULATED CABLES
HALIDES
HALOGEN COMPOUNDS
INFORMATION
MEASURING INSTRUMENTS
NUMERICAL DATA
PERFORMANCE
POWER SUBSTATIONS
POWER SYSTEMS
POWER TRANSMISSION LINES
SULFUR COMPOUNDS
SULFUR FLUORIDES
TRANSFORMERS
TRANSIENTS
UHV AC SYSTEMS
VOLTAGE REGULATORS