The high cost-effectiveness of cool storage in new commercial buildings
Conference
·
· ASHRAE Trans.; (United States)
OSTI ID:5589666
In new commercial buildings with demand meters, thermal storage is already cost-effective. The cheapest strategy, partial storage, displaces two-thirds of cooling demand and can displace 3 GW each year in new U.S. buildings. The more expensive strategy of full-demand avoidance can shift another 2 GW. Partial storage uses a chiller, sized to run continuously. On a summer night, the excess chiller capacity goes to storing coolth, then the next afternoon this coolth is used to supplement the chiller. (This strategy requires the samllest capacity chiller and the smallest volume storage, i.e., the least first cost.) Demand-limited storage minimizes cost of operation by installing a somewhat larger chiller, sized to be able to turn off when power is most expensive. Both chiller and storage must be about 40% larger than what is required for partial storage. Many builders will go only as far as partial storage, which has a payback of less than three years. But from the point of view of society and the utilities, full-peak avoidance will in the long run save money and power plants. We discuss the attractiveness of both strategies for the customer and for the utilities.
- Research Organization:
- Univ. of California, Lawrence Berkeley Lab., Berkeley, CA
- DOE Contract Number:
- AC03-76SF00098
- OSTI ID:
- 5589666
- Report Number(s):
- CONF-850606-
- Conference Information:
- Journal Name: ASHRAE Trans.; (United States) Journal Volume: 91:2B
- Country of Publication:
- United States
- Language:
- English
Similar Records
The control of ice storage systems
Economic analysis of air-conditioning systems with off-peak chilled-water storage. Master's thesis
Economics of cool storage for electric load leveling
Journal Article
·
Mon May 01 00:00:00 EDT 1995
· ASHRAE Journal
·
OSTI ID:69756
Economic analysis of air-conditioning systems with off-peak chilled-water storage. Master's thesis
Technical Report
·
Tue Sep 01 00:00:00 EDT 1981
·
OSTI ID:5188545
Economics of cool storage for electric load leveling
Journal Article
·
Wed Dec 31 23:00:00 EST 1980
· Proc. Am. Power Conf.; (United States)
·
OSTI ID:6344877
Related Subjects
29 ENERGY PLANNING, POLICY, AND ECONOMY
290200 -- Energy Planning & Policy-- Economics & Sociology
32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION
320104* -- Energy Conservation
Consumption
& Utilization-- Commercial & Industrial Buildings-- (-1987)
AIR CONDITIONERS
AIR CONDITIONING
BUILDERS
BUILDINGS
CAPACITY
CAPITALIZED COST
COLD STORAGE
COMMERCIAL BUILDINGS
COMPARATIVE EVALUATIONS
COST
COST BENEFIT ANALYSIS
DECISION MAKING
DEMAND
DESIGN
INSTALLATION
NORTH AMERICA
OPERATION
PAYBACK PERIOD
PEAK LOAD
PERSONNEL
POWER PLANTS
PUBLIC UTILITIES
SHUTDOWNS
SIZE
SOCIAL IMPACT
STORAGE
USA
VOLUME
290200 -- Energy Planning & Policy-- Economics & Sociology
32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION
320104* -- Energy Conservation
Consumption
& Utilization-- Commercial & Industrial Buildings-- (-1987)
AIR CONDITIONERS
AIR CONDITIONING
BUILDERS
BUILDINGS
CAPACITY
CAPITALIZED COST
COLD STORAGE
COMMERCIAL BUILDINGS
COMPARATIVE EVALUATIONS
COST
COST BENEFIT ANALYSIS
DECISION MAKING
DEMAND
DESIGN
INSTALLATION
NORTH AMERICA
OPERATION
PAYBACK PERIOD
PEAK LOAD
PERSONNEL
POWER PLANTS
PUBLIC UTILITIES
SHUTDOWNS
SIZE
SOCIAL IMPACT
STORAGE
USA
VOLUME