Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Examination of insulation wear modes in geothermal logging cables

Conference ·
OSTI ID:5573356

The wear mode of the Tetrafluorethylene (TFE) insulation used on an electrical logging cable is described. The cable examined in this study was used repeatedly in various harsh geothermal environments. Considering the amount of abuse the cable was subjected to, the TFE performed very well. Grooves were formed on the outside of the insulation as a result of the fluid pressure and the loading from the inner layer of metal armor. Also, indentations on the inside of the insulation were caused by the insulation molding to the conductor strands. If this mode of wear were to continue, the conductors would eventually protrude from the insulation and short out against each other or the cable armor. 4 refs., 5 figs.

Research Organization:
Los Alamos National Lab., NM (USA)
DOE Contract Number:
W-7405-ENG-36
OSTI ID:
5573356
Report Number(s):
LA-UR-85-926; CONF-850801-22; ON: DE85009554
Country of Publication:
United States
Language:
English