Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

PLT data acquisition and analysis system

Journal Article · · Rev. Sci. Instrum.; (United States)
DOI:https://doi.org/10.1063/1.1139161· OSTI ID:5565331
The data acquisition and analysis system for PLT (Princeton Large Torus) is being moved from a DEC-10 to a VAX 11/785. Most of the major diagnostics are currently running on the VAX, with approximately 1 Mbyte of data being taken each shot. The system uses the MIT model data system (MDS) for acquisition and archival of data and the PPPL event-controlled scheduler (ECS) for scheduling. The analysis programs use the MDS data retrieval subroutines which deliver correctly calibrated results to the user program.
Research Organization:
Plasma Physics Laboratory, Princeton University, Princeton, New Jersey 08544-0451
OSTI ID:
5565331
Journal Information:
Rev. Sci. Instrum.; (United States), Journal Name: Rev. Sci. Instrum.; (United States) Vol. 57:8; ISSN RSINA
Country of Publication:
United States
Language:
English

Similar Records

Data acquisition for PLT
Conference · Tue Dec 31 23:00:00 EST 1974 · OSTI ID:4111552

TARA data-acquisition and physics analysis system
Conference · Wed May 01 00:00:00 EDT 1985 · Rev. Sci. Instrum.; (United States) · OSTI ID:5197009

Data acquisition system for PLT Neutral Beam Test Stand
Conference · Fri Dec 31 23:00:00 EST 1976 · OSTI ID:5366671