Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Alternate approaches to system EMP response assessment

Technical Report ·
OSTI ID:5560122
The outlined assessment approaches of system EMP response as developed by LLL are based on either experimental low-level simulator excitation or surface current injection testing. The advantages and disadvantages compared to electromagnetic pulse assessment techniques by other organizations are noted. Subthreat excitation of a full-scale system or of scale model on a transient electromagnetics facility is described. This assessment yields the linear external or internal response. A proposed procedure for surface current injection testing (SCIT) of either a full-size or scale model system at the subthreat level or a full-size system at the threat level is discussed. The full-threat testing enables assessment of the system nonlinear internal response. Some of the modeling errors involved in the assessment of EMP response of a real system in a threat environment are briefly discussed.
Research Organization:
California Univ., Livermore (USA). Lawrence Livermore Lab.
DOE Contract Number:
W-7405-ENG-48
OSTI ID:
5560122
Report Number(s):
UCID-18522
Country of Publication:
United States
Language:
English