A new water transmission line convolute, single piece insulator, and double disk feed has been designed and tested on the .125 ohm, 10 TW Proto II accelerator. The water transmission lines have a 5 cm gap to eliminate any water arcing. A two-dimensional magnetic field code was used to calculate the convolute inductance. We used an acrylic insulator as well as a single piece, laminated polycarbonate insulator. They have been succuessfully tested at over 90% of the Shipman criteria for classical insulator breakdown, although the laminations in the polycarbonate insulator failed after a few shots. The anode and cathode each have two pieces and are held together mechanically. The vacuum MITL tapers to a 3 mm minimum gap. The total inductance is 8.4 nH for gas puff loads and 7.8 nH for imploding foil loads. Out of a forward-going energy of 290 kJ, 175 kJ has been delivered past the insulator, and 100 kJ has been successfully delivered to the load.