Title: Prediction of turbulent flow and heat transfer in a ribbed rectangular duct with and without rotation

Journal Article · · Journal of Turbomachinery
DOI:https://doi.org/10.1115/1.2835654· OSTI ID:55497
;  [1]
  1. General Electric Co., Cincinnati, OH (United States)

The present study deals with the numerical prediction of turbulent flow and heat transfer in a 2:1 aspect ratio rectangular duct with ribs don the two shorter sides. The ribs are of square cross section, staggered and aligned normal (90 deg) to the main flow direction. The ratio of rib height to duct hydraulic diameter equals 0.063, and the ratio of rib spacing to rib height equals 10. The duct may be stationary or rotating. The axis of rotation is normal to the axis of the duct and parallel to the ribbed walls (i.e., the ribbed walls form the leading and the trailing faces). The problem is three dimensional and fully elliptic; hence, for computational economy, the present analysis deals only with a periodically fully developed situation where the calculation domain is limited to the region between two adjacent ribs. Turbulence is modeled with the {kappa}-{epsilon} model in conjunction with wall functions. However, since the rib height is small, use of wall functions necessitates that the Reynolds number be kept high. (Attempts to use a two-layer model that permits integration to the wall did not yield satisfactory results and such modeling issues are discussed at length.) Computations are made here for Reynolds number in the range 30,000--100,000 and for Rotation number = 0 (stationary), 0.06, and 0.12. For the stationary case, the predicted heat transfer agrees well with the experimental correlations. Due to the Coriolis-induced secondary flow, rotation is found to enhance heat transfer from the trailing and the side walls, while decreasing heat transfer from the leading face. Relative to the corresponding stationary case, the effect of rotation is found to be less for a ribbed channel as compared to a smooth channel.

Sponsoring Organization:
USDOE
OSTI ID:
55497
Report Number(s):
CONF-930502-; ISSN 0889-504X; TRN: IM9525%%178
Journal Information:
Journal of Turbomachinery, Vol. 117, Issue 2; Conference: 38. ASME international gas turbine and aeroengine congress and exhibition, Cincinnati, OH (United States), 24-27 May 1993; Other Information: PBD: Apr 1995
Country of Publication:
United States
Language:
English

Similar Records

Developing heat transfer and friction in a ribbed rectangular duct with flow separation at inlet
Journal Article · Sat Aug 01 00:00:00 EDT 1992 · Journal of Heat Transfer (Transactions of the ASME (American Society of Mechanical Engineers), Series C); (United States) · OSTI ID:55497

LDA study of the flow development through an orthogonally rotating U-bend of strong curvature and rib-roughened walls
Journal Article · Wed Apr 01 00:00:00 EST 1998 · Journal of Turbomachinery · OSTI ID:55497

An experimental investigation of heat transfer characteristics for turbulent flow over staggered ribs in a square duct
Journal Article · Fri Nov 01 00:00:00 EST 1991 · Experimental Thermal and Fluid Science; (United States) · OSTI ID:55497