Diagnostics for TFTR neutral beam species measurement

Journal Article · · Rev. Sci. Instrum.; (United States)
DOI:https://doi.org/10.1063/1.1138740· OSTI ID:5517564
Five diagnostic systems were used for initial species measurements during tokamak fusion test reactor (TFTR) neutral beam test stand operations involving four ion sources, as well as several different configurations and operating conditions. Initial results were obtained for total neutral species fractions at the beamline input and the beamline output, differential radial profiles of species fractions, angular divergences of species components, species radial power density profiles, and beam impurity components for various conditions.
Research Organization:
Princeton Plasma Physics Laboratory, Princeton University, Princeton, New Jersey 08544
DOE Contract Number:
AC02-76CH03073
OSTI ID:
5517564
Journal Information:
Rev. Sci. Instrum.; (United States), Journal Name: Rev. Sci. Instrum.; (United States) Vol. 57:8; ISSN RSINA
Country of Publication:
United States
Language:
English