Nine Mile Point Unit 1 recirculation piping recontamination. Final report

Technical Report ·
OSTI ID:5511220
Primary recirculation piping at Nine Mile Point-1 was replaced in 1982 and 1983. Measurements have been made of the rate of recontamination of the piping system. Piping from two different vendors contaminated at significantly different rates. Assessment of the pipe manufacturing processes and surface examination indicate that sandblasted material contaminates faster than acid-pickled piping. 8 figs., 5 tabs.
Research Organization:
Radiological and Chemical Technology, Inc., San Jose, CA (USA)
OSTI ID:
5511220
Report Number(s):
EPRI-NP-4182; ON: TI85920191
Country of Publication:
United States
Language:
English

Similar Records

Radionuclide buildup in BWR (boiling water reactor) reactor coolant recirculation piping
Technical Report · Thu Nov 30 23:00:00 EST 1989 · OSTI ID:5198079

Effectiveness and safety aspects of selected decontamination methods for LWRs (light-water reactors): ''The Recontamination Experience''
Conference · Wed Dec 31 23:00:00 EST 1986 · OSTI ID:5360158

Nine Mile Point recirc-piping replacement offers lessons for tomorrow's nuclear repairs
Journal Article · Wed Nov 30 23:00:00 EST 1983 · Power; (United States) · OSTI ID:6987575