The parameters of the subcooled 4ATM helium flow from MTDF refrigerator and helium subcooler proposed to cool the SSC Design 'D' magnet is discussed. The system operating parameters are pressure - 4ATM and temperature - 4.35K. The higher than normal operating pressure is obtained by shutting down the cold turbine (T2) of MTDF refrigerator, and then not J-T the high pressure dense helium gas until after the magnet and liquid return line. The resultant helium temperature at the refrigerator outlet is described and the heat transfer tube length of the subcooler required to cool the flow to the ultimate desired temperature is evaluated.