Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Radon Pressure Differential Project, Phase 1. Florida Radon Research Program. Final report

Technical Report ·
OSTI ID:5504806
The report gives results of tests on 70 central Florida houses to assess and characterize pressure differentials in new (age 5 years or less) Florida houses. Blower door tests determined house airtightness and air distribution system leakage. The 70 houses had an average airtightness of 7.23 air changes per hour at 50 Pa (ACH50). Significant leaks were found in the ductwork in most houses tested, both on the supply and return sides of the air handler. When the air distribution system was sealed off, house ACH50 decreased to 6.42, indicating that 11.2% of the house leak area is in the duct system. Differential pressure measurements were taken between the main body of each house and subslab areas, outdoors, and many locations within the house. These measurements indicated significant pressure differentials in the house due to a number of factors. Return leaks produced a maximum whole-house pressurization of 5.5 Pa. Supply leaks produced a maximum whole-house depressurization of -4.8 Pa. Closed interior doors produced a maximum closed-room pressurization of 37 Pa and a maximum main-body depressurization of -14.8 Pa. Turning on all exhaust fans and interior dryers typically depressurized the house to 0 to -4 Pa.
Research Organization:
Florida Technological Univ., Cape Canaveral, FL (United States). Florida Solar Energy Center
OSTI ID:
5504806
Report Number(s):
PB-92-148519/XAB
Country of Publication:
United States
Language:
English

Similar Records

The effect of varying levels of induced duct leakage on differential pressures in a Florida house
Journal Article · Fri Sep 01 00:00:00 EDT 1995 · American Society for Testing and Materials, Special Technical Publication · OSTI ID:170001

Radon mitigation in schools
Journal Article · Sun Dec 31 23:00:00 EST 1989 · ASHRAE Journal (American Society of Heating, Refrigerating and Air-Conditioning Engineers); (USA) · OSTI ID:6958657

Modeling air flow dynamics in radon mitigation systems: A simplified approach
Journal Article · Thu Oct 31 23:00:00 EST 1991 · Journal of the Air and Waste Management Association; (United States) · OSTI ID:5701595