Investigation of the moving-bed copper oxide process for flue gas cleanup
Book
·
OSTI ID:549622
- Dept. of Energy, Pittsburgh, PA (United States). Pittsburgh Energy Technology Center
- Parsons Power Group, Inc., Pittsburgh, PA (United States)
The Moving-Bed Copper Oxide Process is a dry, regenerable sorbent technique that uses supported copper oxide sorbent to simultaneously remove SO{sub 2} and NO{sub x} emissions from flue gas generated by coal combustion. The process can be integrated into the design of advanced power systems, such as the Low-Emission Boiler System (LEBS) or the High-Performance Power System (HIPPS). This flue gas cleanup technique is currently being evaluated in a life-cycle test system (LCTS) with a moving-bed flue gas contactor at DOE`s Pittsburgh Energy Technology Center. An experimental data base being established will be used to verify reported technical and economic advantages, optimize process conditions, provide scaleup information, and validate absorber and regenerator mathematical models. In this communication, the results from several process parametric test series with the LCTS are discussed. The effects of various absorber and regenerator parameters on sorbent performance (e.g., SO{sub 2} removal) were investigated. Sorbent spheres of 1/8-in diameter were used as compared to 1/16-in sized sorbent of a previous study. Also discussed are modifications to the absorber to improve the operability of the LCTS when fly ash is present during coal combustion.
- OSTI ID:
- 549622
- Report Number(s):
- CONF-960954--
- Country of Publication:
- United States
- Language:
- English
Similar Records
Pilot study of the moving-bed copper oxide process for SO{sub 2} and NO{sub x} control
Design, construction, and operation of a life-cycle test system for the evaluation of flue gas cleanup processes
A sorbent regenerator simulation model in copper oxide flue gas cleanup processes
Conference
·
Tue Jul 01 00:00:00 EDT 1997
·
OSTI ID:490345
Design, construction, and operation of a life-cycle test system for the evaluation of flue gas cleanup processes
Technical Report
·
Thu Nov 30 23:00:00 EST 1995
·
OSTI ID:205845
A sorbent regenerator simulation model in copper oxide flue gas cleanup processes
Journal Article
·
Tue Sep 01 00:00:00 EDT 1998
· Environmental Progress
·
OSTI ID:642275