We present a new technique for measuring the energy spectrum of X rays emitted by high-intensity, medium-voltage flash x-ray sources. The method sorts Compton electrons by drift velocity time-of-flight in a non-uniform magnetic field. We explain the conceptual design of the spectrometer, show how we have modeled it using Monte Carlo methods, and discuss the procedure for unfolding x-ray spectrum information from electron time-of-flight data. The technique appears promising, especially for short-pulse x-ray sources.
Research Organization:
Sandia National Labs., Albuquerque, NM (USA)
DOE Contract Number:
AC04-76DP00789
OSTI ID:
5494152
Report Number(s):
SAND-86-0357C; CONF-860706-13; ON: DE86012950
Country of Publication:
United States
Language:
English