skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Resonance Control Cooling System for the APT/LEDA CCDTL Hot Model

Conference ·
OSTI ID:5493

The Hot Model for the Coupled Cavity Drift Tube Linac (CCDTL) resonance control cooling system (RCCS) for the Low Energy Demonstration Accelerator (LEDA) [1] in support of the Accelerator Production of Tritium (APT) [2] is described. Two hydraulic control loops are described that control the frequency in the CCDTL Hot Model cavity. The two loops supply the required flow to the 32 channels. Control system schema is described to regulate resonant frequency during steady state operation.

Research Organization:
Kansas City Plant, Kansas City, MO (US)
Sponsoring Organization:
US Department of Energy (US)
DOE Contract Number:
AC04-76-DP00613
OSTI ID:
5493
Report Number(s):
KCP-613-6178; TRN: US0302680
Resource Relation:
Conference: 1999 Particle Accelerator Conference, New York City, NY (US), 03/28/1999--04/02/1999; Other Information: PBD: 8 Apr 1999