Thermionic gun control system for the CEBAF (Continuous Electron Beam Accelerator Facility) injector

Conference ·
OSTI ID:5481223
The injector for the CEBAF accelerator must produce a high-quality electron beam to meet the overall accelerator specifications. A Hermosa electron gun with a 2 mm-diameter cathode and a control aperture has been chosen as the electron source. This must be controlled over a wide range of operating conditions to meet the beam specifications and to provide flexibility for accelerator commissioning. The gun is controlled using Computer Automated Measurement and Control (CAMAC IEEE-583) technology. The system employs the CAMAC-based control architecture developed at CEBAF. The control system has been tested, and early operating data on the electron gun and the injector beam transport system has been obtained. This system also allows gun parameters to be stored at the operator location, without paralyzing operation. This paper describes the use of this computer system in the control of the CEBAF electron gun. 2 refs., 6 figs., 1 tab.
Research Organization:
Southeastern Universities Research Association, Newport News, VA (USA). Continuous Electron Beam Accelerator Facility
Sponsoring Organization:
DOE/ER
DOE Contract Number:
AC05-84ER40150
OSTI ID:
5481223
Report Number(s):
DOE/ER/40150-103; CEBAF-PR--89-028; CONF-881049--78; ON: DE90000756
Country of Publication:
United States
Language:
English