Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Quantitative fuel motion determination with the CABRI fast neutron hodoscope; Evaluation methods and results

Journal Article · · Nuclear Technology; (United States)
OSTI ID:5477724
 [1];  [2]
  1. Kernforschungszentrum Karlsruhe GmbH (Germany)
  2. Centre d'Etudes Nucleaires Cadarache, F-13108 St. Paul-lez-Durance (FR)
The fast neutron hodoscope installed at the CABRI reactor in Cadarache, France, is employed to provide quantitative fuel motion data during experiments in which single liquid-metal fast breeder reactor test pins are subjected to simulated accident conditions. Instrument design and performance are reviewed, the methods for the quantitative evaluation are presented, and error sources are discussed. The most important findings are the axial expansion as a function of time, phenomena related to pin failure (such as time, location, pin failure mode, and fuel mass ejected after failure), and linear fuel mass distributions with a 2-cm axial resolution. In this paper the hodoscope results of the CABRI-1 program are summarized.
OSTI ID:
5477724
Journal Information:
Nuclear Technology; (United States), Journal Name: Nuclear Technology; (United States) Vol. 96:3; ISSN NUTYB; ISSN 0029-5450
Country of Publication:
United States
Language:
English