Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

TFTR initial operations

Technical Report ·
DOI:https://doi.org/10.2172/5459321· OSTI ID:5459321
The Tokamak Fusion Test Reactor (TFTR) has operated since December 1982 with ohmically heated plasmas. Routine operation with feedback control of plasma current, position, and density has been obtained for plasmas with I/sub p/ approx. = 800 kA, a = 68 cm, R = 250 cm, and B/sub t/ = 27 kG. A maximum plasma current of 1 MA was achieved with q approx. = 2.5. Energy confinement times of approx. 150 msec were measured for hydrogen and deuterium plasmas with anti n/sub e/ approx. = 2 x 10/sup 13/ cm/sup -3/, T/sub e/ (0) approx. = 1.5 keV, T/sub i/ (0) approx. = 1.5 keV, and Z/sub eff/ approx. = 3. The preliminary results suggest a size-cubed scaling from PLT and are consistent with Alcator C scaling where tau approx. nR/sup 2/a. Initial measurements of plasma disruption characteristics indicate current decay rates of approx. 800 kA in 8 ms which is within the TFTR design requirement of 3 MA in 3 ms.
Research Organization:
Princeton Univ., NJ (USA). Plasma Physics Lab.
DOE Contract Number:
AC02-76CH03073
OSTI ID:
5459321
Report Number(s):
PPPL-2051; ON: DE84004302
Country of Publication:
United States
Language:
English