Impact of the humidity pump on indoor environments. Final report, August 1989-November 1990
Technical Report
·
OSTI ID:5458362
The impact of the humidity pump, (a newly developed, gas-fired, liquid desiccant, make-up air conditioning unit) on the indoor air environment of two office buildings was investigated during a two month field program. The study generated a data base and gained insights on indoor air quality (IAQ), comfort, and ventilation parameters of each building operating under routine conditions. The objective of the study was to determine the impact of the humidity pump on (1) indoor pollution concentration levels; (2) comfort parameters as perceived by occupants of and visitors to each building; and (3) building ventilation (energy) parameters. Each objective was attained by testing the null hypothesis (Operation of the humidity pump has no impact.) The null hypothesis was tested on occupant exposure levels. Consequently, it was rejected only if the humidity pump affects potential factors that may alter significantly pollutant concentrations, comfort levels, and ventilation rates. Operation of the humidity pump affects levels of volatile organic compounds and microbiological conditions. The humidity pump did not affect comfort and ventilation parameters.
- Research Organization:
- IIT Research Inst., Chicago, IL (United States)
- OSTI ID:
- 5458362
- Report Number(s):
- PB-91-206763/XAB; CNN: GRI-5086-293-1339
- Country of Publication:
- United States
- Language:
- English
Similar Records
Children's exposure to indoor air in urban nurseries-part I: CO{sub 2} and comfort assessment
Ventilation research: A review of recent indoor air quality literature. Final report, October 1993-March 1994
Field Validation of a Smart Energy Recovery Ventilation System Using Low-Cost Indoor Air Quality Sensors
Journal Article
·
Wed Jul 15 00:00:00 EDT 2015
· Environmental Research
·
OSTI ID:22483295
Ventilation research: A review of recent indoor air quality literature. Final report, October 1993-March 1994
Technical Report
·
Thu Sep 01 00:00:00 EDT 1994
·
OSTI ID:6658601
Field Validation of a Smart Energy Recovery Ventilation System Using Low-Cost Indoor Air Quality Sensors
Technical Report
·
Sun Feb 28 23:00:00 EST 2021
·
OSTI ID:1772579
Related Subjects
54 ENVIRONMENTAL SCIENCES
540120* -- Environment
Atmospheric-- Chemicals Monitoring & Transport-- (1990-)
AIR CONDITIONING
AIR POLLUTION
AIR POLLUTION MONITORING
BUILDINGS
CONTROL
ECOLOGICAL CONCENTRATION
HUMIDITY CONTROL
INDOOR AIR POLLUTION
MATTER
MONITORING
OFFICE BUILDINGS
ORGANIC COMPOUNDS
POLLUTION
VENTILATION
VOLATILE MATTER
540120* -- Environment
Atmospheric-- Chemicals Monitoring & Transport-- (1990-)
AIR CONDITIONING
AIR POLLUTION
AIR POLLUTION MONITORING
BUILDINGS
CONTROL
ECOLOGICAL CONCENTRATION
HUMIDITY CONTROL
INDOOR AIR POLLUTION
MATTER
MONITORING
OFFICE BUILDINGS
ORGANIC COMPOUNDS
POLLUTION
VENTILATION
VOLATILE MATTER