Application of A150-plastic equivalent gases in microdosimetric measurements
Neutron dosimetry measurements with ionization chambers, for the most part, employ tissue equivalent plastic-walled cavities (Shonka A150) filled with either air or a methane-base tissue-like gas. The atomic composition of TE-gas and A150 plastic are not matched and are quite dissimilar from muscle. Awschalom and Attix (1980) have partially resolved the problem by formulating a novel A150-plastic equivalent gas. This establishes a homogeneous wall-gas cavity dosimeter for neutron measurements and confines the necessary corrections to the applications of kerma ratios. In this report, we present measurements of applications of two A150-plastic equivalent gases in a low pressure spherical proportional counter. Gas gains and alpha-particle resolutions were determined. For these A150-mixtures as well as a methane-based TE-gas and an Ar-CO/sub 2/ mixture, we report measurements of event size distributions from exposure to a beam of 14.8 MeV neutrons.
- Research Organization:
- Wisconsin Univ., Madison (USA). Dept. of Medical Physics
- DOE Contract Number:
- AS02-76EV01105
- OSTI ID:
- 5456213
- Report Number(s):
- DOE/EV/01105-284; ON: DE82009368
- Country of Publication:
- United States
- Language:
- English
Similar Records
Characteristics of various tissue and A150-plastic equivalent gas mixtures for microdosimetric applications
Application of A150 plastic-equivalent gas in A150 plastic ionization chambers for Co-60. gamma. rays and 14. 8-MeV neutrons
Performance characteristics of A150 plastic-equivalent gases in A150 plastic proportional counters for 14. 8-MeV neutrons
Technical Report
·
Thu Dec 31 23:00:00 EST 1981
·
OSTI ID:5018035
Application of A150 plastic-equivalent gas in A150 plastic ionization chambers for Co-60. gamma. rays and 14. 8-MeV neutrons
Journal Article
·
Sat May 01 00:00:00 EDT 1982
· Med. Phys.; (United States)
·
OSTI ID:5497639
Performance characteristics of A150 plastic-equivalent gases in A150 plastic proportional counters for 14. 8-MeV neutrons
Journal Article
·
Sun Jul 01 00:00:00 EDT 1984
· Med. Phys.; (United States)
·
OSTI ID:6667310
Related Subjects
61 RADIATION PROTECTION AND DOSIMETRY
654003 -- Radiation & Shielding Physics-- Neutron Interactions with Matter
655003* -- Medical Physics-- Dosimetry
73 NUCLEAR PHYSICS AND RADIATION PHYSICS
BARYONS
DOSIMETRY
ELEMENTARY PARTICLES
FAST NEUTRONS
FERMIONS
FLUIDS
GASES
HADRONS
IONIZATION CHAMBERS
KERMA
MATERIALS
MEASURING INSTRUMENTS
MICRODOSIMETRY
NEUTRON DOSIMETRY
NEUTRONS
NUCLEONS
RADIATION DETECTORS
TISSUE-EQUIVALENT MATERIALS
654003 -- Radiation & Shielding Physics-- Neutron Interactions with Matter
655003* -- Medical Physics-- Dosimetry
73 NUCLEAR PHYSICS AND RADIATION PHYSICS
BARYONS
DOSIMETRY
ELEMENTARY PARTICLES
FAST NEUTRONS
FERMIONS
FLUIDS
GASES
HADRONS
IONIZATION CHAMBERS
KERMA
MATERIALS
MEASURING INSTRUMENTS
MICRODOSIMETRY
NEUTRON DOSIMETRY
NEUTRONS
NUCLEONS
RADIATION DETECTORS
TISSUE-EQUIVALENT MATERIALS