Performance evaluation of molten salt thermal storage systems
The molton salt thermal storage system located at the Central Receiver Test Facility (CRTF) was recently subjected to thermal performance tests. The system is composed of a hot storage tank containing molten nitrate salt at a temperature of 1050/sup 0/F and a cold tank containing 550/sup 0/F salt with associated valves and controls. It is rated at 7 MWht and was designed and installed by Martin Marietta Corporation in 1982. The results of these tests were used to accomplish four objectives: (1) to compare the current thermal performance of the system with the performance of the system soon after it was installed, (2) to validate a dynamic computer model of the system, (3) to obtain an estimate of an annual system efficiency for a hypothetical commercial scale 1200 MWht system and (4) to compare the performance of the CRTF system with thermal storage systems developed by the European solar community. 4 refs., 4 figs., 2 tabs.
- Research Organization:
- Sandia National Labs., Albuquerque, NM (USA); Deutsche Forschungs- und Versuchsanstalt fuer Luft- und Raumfahrt e.V., Koeln (Germany, F.R.)
- DOE Contract Number:
- AC04-76DP00789
- OSTI ID:
- 5453773
- Report Number(s):
- SAND-87-1497C; CONF-880420-1; ON: DE87014645
- Country of Publication:
- United States
- Language:
- English
Similar Records
Molten Salt Thermal Energy Storage Subsystem Research Experiment. Volume I. Executive summary
Molten Salt Thermal Energy Storage Subsystem Research Experiment. Volume II. Final technical report
Related Subjects
140702* -- Solar Thermal Power Systems-- Central Receiver
25 ENERGY STORAGE
250600 -- Energy Storage-- Thermal
CENTRAL RECEIVER TEST FACILITY
COMPARATIVE EVALUATIONS
COMPUTERIZED SIMULATION
DATA
ENERGY TRANSFER
EQUIPMENT
EXPERIMENTAL DATA
HEAT TRANSFER
INFORMATION
MOLTEN SALTS
NUMERICAL DATA
PERFORMANCE TESTING
SALTS
SIMULATION
TEST FACILITIES
TESTING
THEORETICAL DATA
THERMAL ENERGY STORAGE EQUIPMENT