Evaluation of a cyclone dust collector for high-temperature, high-pressure particulate control

Journal Article · · Ind. Eng. Chem. Process Des. Dev.; (United States)
DOI:https://doi.org/10.1021/i200016a027· OSTI ID:5443213
The performance of conventional cyclones operating at temperatures up to 900 C and pressures up to 900 kPa on flue gas from a pressurized fluidized bed coal combustion unit was measured. The cyclones were very efficient, generally removing particulates to a level of 0,04 to 0.7 g/m/sub 3/ at the exit of a three-stage cyclone system. Cyclone performance was measured using a total filter/Coulter Counter technique and cascade impactor to measure the particulate size distribution. The two methods gave comparable results.
OSTI ID:
5443213
Journal Information:
Ind. Eng. Chem. Process Des. Dev.; (United States), Journal Name: Ind. Eng. Chem. Process Des. Dev.; (United States) Vol. 21:1; ISSN IEPDA
Country of Publication:
United States