Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Characterization and equalization of the AC responses of the corrector magnets for the APS local orbit feedback system

Conference ·
OSTI ID:543624
Local feedback for the APS storage ring uses local bumps to control the position and angle of the positron beam through each x-ray source point. Induced eddy currents in the aluminum vacuum chamber dominate the AC characteristics of the corrector magnetic fields. Small differences in the geometries at each magnet location change the eddy current effects and result in bump closure errors which must be reduced in order to minimize the coupling between each of the many local loops and the global control loop. By a combination of flux-damping coils, flux-shielding copper sheets, and a set of steel laminations for end-flux clamping, the differences of the eddy current effects between two corrector magnets were reduced from 0.18 Gm/A to 0.035 Gm/A in the frequency span of 0.1-100 Hz.
Research Organization:
Argonne National Lab., IL (United States)
Sponsoring Organization:
USDOE Office of Energy Research, Washington, DC (United States)
DOE Contract Number:
W-31109-ENG-38
OSTI ID:
543624
Report Number(s):
ANL/ASD/CP--92292; CONF-970503--; ON: DE97053291
Country of Publication:
United States
Language:
English

Similar Records

Compensation for the effect of vacuum chamber eddy current by digital signal processing for closed orbit feedback
Conference · Thu Jul 01 00:00:00 EDT 1993 · OSTI ID:10175712

Real-time orbit feedback at the APS
Journal Article · Wed Dec 09 23:00:00 EST 1998 · AIP Conference Proceedings · OSTI ID:21202357

Real-time orbit feedback at the APS
Journal Article · Mon Nov 30 23:00:00 EST 1998 · AIP Conference Proceedings · OSTI ID:344455