Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Evaluation of a passive containment cooling system for a simplified BWR (boiling water reactor)

Conference · · Transactions of the American Nuclear Society; (United States)
OSTI ID:5434635
;  [1]; ;  [2]
  1. Nippon Atomic Industry Group Company, Ltd., Kawasaki (Japan)
  2. Toshiba Corporation, Yokohama (Japan)

Simplified boiling water reactors (BWRs) are characterized for the adoption of a passive containment cooling system (PCCS) and a passive emergency core cooling system (ECCS). TOSPAC, which had been developed as the preliminary design code for several PCCS concepts, was compared with TRAC for verification. TOSPAC analyses were also performed to show the effectiveness of the isolation condenser (IC) as a PCCS over a wide range of break spectra. The selected reference plant for the analysis is a natural circulation BWR plant with 1,800-MW(thermal) power. The ECCS consists of a gravity-driven cooling system (GDCS) and depressurization valves. The IC and drywell cooler are considered for the PCCS. The IC units and drywell coolers are placed in the IC pool and GDCS pool, respectively.

OSTI ID:
5434635
Report Number(s):
CONF-891103--
Journal Information:
Transactions of the American Nuclear Society; (United States), Journal Name: Transactions of the American Nuclear Society; (United States) Vol. 60; ISSN TANSA; ISSN 0003-018X
Country of Publication:
United States
Language:
English