Results of a scoping study in which natural-gas-fueled combustion turbines are utilized to repower existing oil-fired/gas-fired steam turbine generating units are presented. A representative range of unit sizes, 80 to 800 MW, was investigated. Depending on the unit and repowering configuration, repowering resulted in calculated heat rate reductions of 7% to 18% and calculated increased unit outputs of 28% to 165%. The estimated installed costs per kW of added new generating capacity ranged from $363/kW to $589/kW, again depending on the unit and repowering configuration. Design considerations for various repowering configurations are also presented. 23 figs., 21 tabs.
Research Organization:
Florida Power and Light Co., Juno Beach (USA)
OSTI ID:
5434434
Report Number(s):
EPRI-AP-5611; ON: TI88920169
Country of Publication:
United States
Language:
English

Similar Records

Repowering options for steam power plants
Conference · Tue Dec 31 23:00:00 EST 1991 · Proceedings of the American Power Conference; (United States) · OSTI ID:7309531

Combustion turbine repowering of reheat steam power plants. Final report
Technical Report · Tue Aug 01 00:00:00 EDT 1978 · OSTI ID:6677373

Repowering as a solution to lower generating costs
Conference · Wed Dec 31 23:00:00 EST 1975 · Proc. Am. Power Conf.; (United States) · OSTI ID:5320693