Title: Poster presentation Sandia helicopter acoustic detector

Conference · · Nucl. Mater. Manage.; (United States)
OSTI ID:5429774

In reviewing the safeguards plans for several proposed fuel cycle facilities, the advantages of a short-range helicopter detector became apparent. The main buildings of these new designs are generally hardened so as to provide significant delay to a helicopter-borne adversary team. Under these circumstances the sensor is only required to detect helicopters which are in their final landing phase and at close range (less than 75 meters). This paper describes the Sandia detector, which is designed to only look at spectral lines between 20 and 40 Hz, and depends upon the harmonic content of the rotor pulses for detecting the lower rotor speed helicopters. 1 ref.

Research Organization:
Sandia Natl Lab, USA
OSTI ID:
5429774
Report Number(s):
CONF-810706-; TRN: 82-013139
Journal Information:
Nucl. Mater. Manage.; (United States), Vol. 10; Conference: Institute of Nuclear Materials Management conference, San Francisco, CA, USA, 13 Jul 1981
Country of Publication:
United States
Language:
English