The objective of this program is to conserve gas by improving the seasonal efficiency of gas-fired appliances. This can be achieved by evaluating the effectiveness of retrofit techniques for improving existing appliances and by evaluating advanced technology with reported high or improved efficiency. The cyclic utilization efficiency test room was used to estimate the seasonal efficiency of two advanced technology appliances: an instantaneous hot water boiler and a condensing furnace. Potential energy savings were estimated for a contemporary counterflow furnace when retrofitted with the following techniques: (a) derate, (b) vent restriction, (c) vent dampers, and (d) combination of the above. Gas interchangeability studies were conducted with a flash back and yellow tip gas on two appliances retrofitted for energy savings.