The nitrogen effect on Type 304L austenitic stainless steel weld metal welded with a GTA (Gas Tungsten Arc) system under ambient and hyperbaric conditions

Technical Report ·
OSTI ID:5419684
Small amounts of nitrogen were injected into Type 304L austenitic stainless steel weld metal. This was accomplished by using an Ar-N/sub 2/ shield gas mixture in combination with a controlled argon atmosphere on autogeneous Gas Tungsten Arc (GTA) welds. Weld metal nitrogen as a function of nitrogen shield gas content and applied pressure was examined. Nitrogen shield gas contents above 4% were found to have a major effect on the weld metal microstructure. The base metal nitrogen did not influence the nitrogen solubility reaction or solidification behavior during welding. For Type 304L austenitic stainless steel, a nitrogen coefficient of 13.4 was determined for the nickel equivalent expression. 63 refs., 19 figs., 4 tabs.
Research Organization:
Rockwell International Corp., Golden, CO (USA). Rocky Flats Plant
DOE Contract Number:
AC04-76DP03533
OSTI ID:
5419684
Report Number(s):
RFP-4202; ON: DE88006489
Country of Publication:
United States