Title: Evaluation of methods for simultaneous collection and determination of nicotine and polynuclear aromatic hydrocarbons in indoor air

Journal Article · · Environmental Science and Technology; (United States)
DOI:https://doi.org/10.1021/es00075a007· OSTI ID:5397819
;  [1];  [2]
  1. Battelle, Columbus, OH (USA)
  2. Environmental Protection Agency, Research Triangle Park, NC (USA)

A study was performed to determine whether one sampling system and one analytical method can be used to collect and measure both polynuclear aromatic hydrocarbons (PAHs) and nicotine. PAH collection efficiencies for both XAD-2 and XAD-4 adsorbents were very similar, but nicotine collection efficiency was greater for XAD-4. Spiked perdeuterated PAHs were retained well in both adsorbents after exposure to more than 300 m{sup 3} of air. A two-step Soxhlet extraction, dichloromethane followed by ethyl acetate, was used to remove nicotine and PAHs from XAD-4. The extract was analyzed by positive chemical ionization or electron impact gas chromatography/mass spectrometry (GC/MS) to determine nicotine and PAHs. It is shown that one sampling system (quartz fiber filter and XAD-4 in series) and one analytical method (Soxhlet extraction and GC/MS) can be used for both nicotine and PAHs in indoor.

OSTI ID:
5397819
Journal Information:
Environmental Science and Technology; (United States), Vol. 24:5; ISSN 0013-936X
Country of Publication:
United States
Language: