Immediate post-exposure effects of high-peak-power microwave pulses on operant behavior of Wistar rats
- ERC BioServices Corporation, Gaithersburg, MD (USA)
Behavioral effects of high-peak-power microwave pulses on Wistar rats were studied by operant schedules. Each of twelve rats that had been trained to press a lever to receive food pellets was assigned randomly in groups of four to three different schedules of reinforcement: fixed-ratio (FR), variable-interval (VI), and differential-reinforcement-of-low-rates (DRL). After achieving a steady baseline performance, each animal was exposed for 10 min to 1.25-GHz microwave radiation at 1-MW peak-power (10-microseconds pulse width). Each pulse produced a peak whole-body SA and SAR of 2.1 J/kg and 0.21 MW/kg. Total doses (SAs) were set to 0.50, 1.5, 4.5, and 14 kJ/kg by adjusting the pulse-repetition rate. The corresponding time-averaged whole-body SARs were 0.84, 2.5, 7.6, and 23 W/kg. A microwave-transparent animal holder was used to keep the animal's body axis parallel to the E-field. Exposures at the highest dose caused an average colonic temperature rise of 2.5C and these animals failed to respond at all for about 13 minutes after the exposure. Their colonic temperatures had decreased to 1.1C, or less, above their pre-exposure (normal) temperature level when they began to respond. The FR and VI animals failed to reach their baseline levels of performance thereafter, while those on the DRL schedule displayed variable effects. No behavioral effects were found at the lower dose levels. It is concluded that the behavioral perturbations produced by pulsed microwave irradiation were thermal in nature.
- OSTI ID:
- 5387824
- Journal Information:
- Bioelectromagnetics (New York); (United States), Vol. 12:3; ISSN 0197-8462
- Country of Publication:
- United States
- Language:
- English
Similar Records
Comparative effects of pulsed and continuous-wave 2. 8-GHz microwaves on temporally defined behavior
Operations and management of government-owned - contractor-operated microwave exposure facility. Volume 1. Effects of high-power pulsed microwaves on rats responding at high, moderate, and low response rates. Final report, 3 January 1985-2 January 1988
Related Subjects
MICROWAVE RADIATION
BIOLOGICAL EFFECTS
RATS
BEHAVIOR
BODY TEMPERATURE
MICROWAVE AMPLIFIERS
AMPLIFIERS
ANIMALS
ELECTROMAGNETIC RADIATION
ELECTRONIC EQUIPMENT
EQUIPMENT
MAMMALS
MICROWAVE EQUIPMENT
RADIATIONS
RODENTS
VERTEBRATES
560400* - Other Environmental Pollutant Effects