Amp-hour counting charge control for photovoltaic hybrid power systems

Conference ·
OSTI ID:537319
 [1];  [2]
  1. Sandia National Labs., Albuquerque, NM (United States)
  2. Biri Systems, Ithaca, NY (United States)

An amp-hour counting battery charge control algorithm has been defined and tested using the Digital Solar Technologies MPR-9400 microprocessor based photovoltaic hybrid charge controller. This work included extensive laboratory and field testing of the charge algorithm on vented lead-antimony and valve regulated lead-acid batteries. The test results have shown that with proper setup amp-hour counting charge control is more effective than conventional voltage regulated sub-array shedding in returning the lead-acid battery to a high state of charge.

Research Organization:
Sandia National Labs., Albuquerque, NM (United States)
Sponsoring Organization:
USDOE Assistant Secretary for Energy Efficiency and Renewable Energy, Washington, DC (United States)
DOE Contract Number:
AC04-94AL85000
OSTI ID:
537319
Report Number(s):
SAND--97-2456C; CONF-970953--; ON: DE98000558
Country of Publication:
United States
Language:
English

Similar Records

Amp-hour counting control for PV hybrid power systems
Conference · Sun Jun 01 00:00:00 EDT 1997 · OSTI ID:519115

Evaluation of solar photovoltaic energy storage for aids to navigation. Interim report
Technical Report · Fri Oct 31 23:00:00 EST 1980 · OSTI ID:5779511

Improved photovoltaic battery chargers for lower maintenance and higher efficiency
Conference · Wed Sep 01 00:00:00 EDT 1982 · Conf. Rec. IEEE Photovoltaic Spec. Conf.; (United States) · OSTI ID:5489182