Strategic petroleum reserve (SPR): oil-storage cavern, Sulphur Mines 6 certification tests and analysis. [Louisiana]

Technical Report ·
DOI:https://doi.org/10.2172/5372602· OSTI ID:5372602
Well leak tests and a cavern pressure test were conducted in June and July 1981 and indicated that oil leakage from the cavern is unlikely to exceed the DOE criterion if oil is stored at near atmospheric wellhead brine pressures and higher pressures are only used for short periods of oil fill and withdrawal. The data indicate that cavern structural failure during oil storage is unlikely and that there was no leakage from cavern 6 to the adjacent cavern 7. Because of the proximity of cavern 6 to cavern 7, it is recommended that a similar type of oil be stored in these two caverns.
Research Organization:
Sandia National Labs., Albuquerque, NM (USA)
DOE Contract Number:
AC04-76DP00789
OSTI ID:
5372602
Report Number(s):
SAND-81-2068; ON: DE82017123
Country of Publication:
United States
Language:
English