Extra-regulatory impact tests and analyses of the structural evaluation test unit
The structural evaluation test unit is roughly equivalent to a 1/3 scale model of a high level waste rail cask. The test unit was designed to just meet the requirements of NRC Regulatory Guide 7.6 when subjected to a 9 m (30 ft) free drop resulting in an impact velocity of 13.4 m/s (30 mph) onto an unyielding target in the end-on orientation. The test unit was then subjected to impacts with higher velocities to determine the amount of built-in conservatism in this design approach. Test impacts of 13.4, 20.1 and 26.8 m/s (30, 45, and 60 mph) were performed. This paper will describe the design, testing, and comparison of measured strains and deformations to the equivalent analytical predictions.
- Research Organization:
- Sandia National Labs., Albuquerque, NM (United States)
- Sponsoring Organization:
- USDOE, Washington, DC (United States)
- DOE Contract Number:
- AC04-94AL85000
- OSTI ID:
- 53683
- Report Number(s):
- SAND--95-0759C; CONF-950740--32; ON: DE95011015
- Country of Publication:
- United States
- Language:
- English
Similar Records
Comparison of the IAEA unyielding surface to various yielding targets
Target effects on package response: An experimental and analytical evaluation