A general algorithm for treatment plan isodose line plotting is described which is particularly useful for pen plotters. Unlike other methods of plotting isodose lines, this algorithm is designed specifically to reduce pen motion, thereby reducing plotting time and wear on the transport mechanism. Points with the desired dose value are extracted from the dose matrix and stored, sorted into continuous contours, and then plotted. This algorithm has been implemented on DEC PDP-11/60 and VAX-11/780 computers for use with two models of Houston Instrument pen plotters, two models of Tektronix vector graphics terminals, a DEC VT125 raster graphics terminal, and a DEC VS11 color raster graphics terminal. Its execution time is similar to simpler direct-plotting methods.