Title: Design and test of a 40-kV, 80-A, 10-msec, neutral-beam power supply series

Conference ·
OSTI ID:5366729

To meet neutral-beam source requirements, a combination series switch/regulator system has been developed that can provide up to 40-kV at 80A output for 10-ms from the continuously decaying voltage of a charged capacitor bank. The system uses 100% feedback control of a series hard tube regulator. This feedback regulator is able to maintain a 40-kV output level for 100% load variations while the source voltage for the capacitor bank is drained from an initial 55-kV down to as low as 43-kV during a 10-ms pulse. In addition to controlling the output voltage, the series regulator tube also serves the dual role of a disconnect or interrupt switch at the end of each pulse and during the frequent occurrence of a neutral-beam source fault. In the interrupt mode, complete disconnect is achieved in less than 2-..mu..s after first observance of a fault condition; recovery times to normal operation of less than 10-..mu..s after fault clearance can be attained if desired.

Research Organization:
California Univ., Livermore (USA). Lawrence Livermore Lab.
DOE Contract Number:
W-7405-ENG-48
OSTI ID:
5366729
Report Number(s):
UCRL-79673; CONF-771029-11; TRN: 78-003093
Resource Relation:
Conference: 7. symposium on fusion research project, Knoxville, TN, USA, 25 Oct 1977
Country of Publication:
United States
Language:
English