Inhibitor-injection program showing early promise
Journal Article
·
· Oil and Gas Journal; (United States)
OSTI ID:5366267
- Alyeska Pipeline Service Co., Anchorage, AK (US)
This paper reports on the treatment system implemented last year at Trans-Alaska Pipeline's pump stations which employed chemical inhibitors in a large-scale, corrosion-mitigation program. Ultrasonic inspection in 1988 revealed internal corrosion predominantly in low-velocity piping. There, emulsified water had precipitated out of the crude oil and supported microbial corrosion. TAPS developed a systems of manual batch treatment to treat the numerous dead legs in the pump-station facilities along with procedures for monitoring inhibitor effectiveness.
- OSTI ID:
- 5366267
- Journal Information:
- Oil and Gas Journal; (United States), Journal Name: Oil and Gas Journal; (United States) Vol. 89:19; ISSN 0030-1388; ISSN OIGJA
- Country of Publication:
- United States
- Language:
- English