Measurement of pressure, fluidized bed level, and density in the Synthane Pilot Plant coal gasifier

Conference ·
OSTI ID:5365793
Fluid bed densities and levels are usually obtained from measurement of differential pressures between taps with a known vertical separation. Historically, this measurement has been difficult in high pressure coal gasification processes primarily due to plugging of the pressure taps and process instrument tubing. Likewise, the achievement of accurate and reliable pressure and differential pressure recordings is affected by similar circumstances. These typical problems were experienced at the SYNTHANE Pilot Plant at Bruceton which is operated for the U.S. Energy Research and Development Administration by the C.E. Lummus Company. Major changes were required in instrument location and selection, piping configuration, and methods of purging. Consistent and accurate data is now obtained. Recommendations for the installation and operation of such instruments are given.
Research Organization:
Lummus Co., Bloomfield, N.J. (USA)
Sponsoring Organization:
US Energy Research and Development Administration (ERDA)
OSTI ID:
5365793
Report Number(s):
COO-0003-7; CONF-770729-3
Country of Publication:
United States
Language:
English