Development of the switching components for ZT-40
Conference
·
OSTI ID:5364970
Switching of the main capacitor banks for ZT-40 will be accomplished by spark gap switches. Initially, there will be 576 start switches and 288 crowbar switches. A development program is under way to develop three switches; (1) a versatile start switch, which can be used for both the I/sub z/ and the I/sub theta/ capacitor banks, with a wide operating voltage range, (2) a crowbar switch which is capable of crowbarring the circuit without the power crowbar bank, and (3) a power crowbar switch, which can handle 50 to 100 coulombs, so that a large number of crowbar switches will not be required when the power crowbar circuit is added. The problems with the start switches and the first crowbar switch have been solved, or alleviated. The development of a power crowbar switch has just begun.