skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Heated mine room and pillar secondary creep response

Technical Report ·
DOI:https://doi.org/10.2172/5363538· OSTI ID:5363538

Heated salt mine room and pillar simulations have been performed to provide information regarding parameters affecting room closure rates to designers of radioactive waste isolation facilities. A coupled secondary creep and heat transfer formulation with large strain capabilities was used to assess the effects of variations in creep law parameters, thermal properties, imposed boundary conditions, temporal integration, and meshing resolution on room closure rates. Results indicate that the greatest effect results from variations in parameters appearing in the creep constitutive equation.

Research Organization:
Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)
DOE Contract Number:
AC04-76DP 00789
OSTI ID:
5363538
Report Number(s):
SAND-79-1199; TRN: 80-010447
Country of Publication:
United States
Language:
English