Quantitation of regional myocardial blood flow (MBF) in absolute terms with positron emission tomography (PET) has been difficult to achieve in part because of errors induced by the relatively low spatial resolution of current tomographic instruments. We previously demonstrated that MBF could be accurately measured over a wide range of flows after intravenous administration of H2 15O when the arterial input function and myocardial radiotracer content were measured directly. To extend this quantitative approach for noninvasive estimates of MBF with PET. We recently developed and implemented a novel mathematical approach whereby partial volume and spillover effects were estimated along with flow within the operational one-compartment flow equation. Noninvasive estimates of flow correlated closely with flow measured directly with radiolabeled microspheres. In the present study, with the use of a commercially available cardiac phantom, we assessed our ability to obtain true time-activity curves from observed PET data contaminated by partial volume and spillover effects. Computer simulations demonstrated that the approach developed is relatively insensitive to most potential sources of error, but is sensitive to timing discrepancies between the arterial input function and the tissue time-activity curve. Implementation of this approach provides accurate quantitation of regional MBF in absolute terms and should be useful in noninvasive evaluation of the efficacy of treatments designed to enhance nutritional perfusion in human subjects.
- OSTI ID:
- 5361906
- Journal Information:
- Journal of Computer Assisted Tomography; (USA), Vol. 13:5; ISSN 0363-8715
- Country of Publication:
- United States
- Language:
- English
Similar Records
Noninvasive quantitation of myocardial blood flow in human subjects with oxygen-15-labeled water and positron emission tomography
Patient motion effects on the quantification of regional myocardial blood flow with dynamic PET imaging
Related Subjects
HEART
POSITRON COMPUTED TOMOGRAPHY
MYOCARDIUM
BLOOD FLOW
DATA COVARIANCES
MATHEMATICAL MODELS
MICROSPHERES
OXYGEN 15
PHANTOMS
SPATIAL RESOLUTION
TRACER TECHNIQUES
WATER
BETA DECAY RADIOISOTOPES
BETA-PLUS DECAY RADIOISOTOPES
BODY
CARDIOVASCULAR SYSTEM
COMPUTERIZED TOMOGRAPHY
DIAGNOSTIC TECHNIQUES
EMISSION COMPUTED TOMOGRAPHY
EVEN-ODD NUCLEI
HYDROGEN COMPOUNDS
ISOTOPE APPLICATIONS
ISOTOPES
LIGHT NUCLEI
MINUTES LIVING RADIOISOTOPES
MOCKUP
MUSCLES
NUCLEI
ORGANS
OXYGEN COMPOUNDS
OXYGEN ISOTOPES
RADIOISOTOPES
RESOLUTION
STRUCTURAL MODELS
TOMOGRAPHY
550601* - Medicine- Unsealed Radionuclides in Diagnostics