Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Rheological characterization of crosslinked and delayed crosslinked fracturing fluids using a closed-loop pipe viscometer

Conference · · Soc. Pet. Eng. AIME, Pap.; (United States)
OSTI ID:5360858
A closed-loop, high-temperature pipe viscometer was used to evaluate the effects that shear intensity, shear duration, temperature, and time have on the apparent viscosity of cross-linked fracturing fluids. Results indicate that much higher gel viscosity can be obtained in the fracture with certain types of delayed cross-linking agents than can be achieved with most of the conventional titanate cross-linkers so widely used in the industry. The maximum achievable apparent viscosity reached by either the titanate or zirconate cross-linked gels studied appears to be most affected by the level of shear or energy input encountered during the initial cross-linking phase.
Research Organization:
BJ-Hughes Services
OSTI ID:
5360858
Report Number(s):
CONF-8310121-
Conference Information:
Journal Name: Soc. Pet. Eng. AIME, Pap.; (United States) Journal Volume: SPE12028
Country of Publication:
United States
Language:
English