Title: Field testing of UF/sub 6/ cylinder gamma-ray measuring equipment for international safeguards

Technical Report ·
OSTI ID:5359331

Two portable intrinsiIAEA (high-purity) Germanium (HP Ge) detectors, a Davidson portable multichannel analyzer (MCA), and accessory equipment were field-tested on product and feed UF/sub 6/ cylinders at the Oak Ridge Gaseous Diffusion Plant. These latter two instruments were not available to UCC-ND at the time of the field tests were designed to assess the usefulness of the above equipment for safeguards; specifically, each cylinder's average /sup 235/U assay was determined by gamma spectrometry and the results were compared statistically with assays obtained previously by mass spectrometry for the same cylinders. This comparison was pivotal to show that the HP Ge detectors can produce results acceptable statistically, and that they can be used with confidence in field measurements. The portable HP Ge detectors are rugged for field use and are most useful in determining /sup 235/U enrichment in UF/sub 6/ cylinders during international safeguards inspections at enrichment plants. Aside from their high resolution and light weight, they can be stored and transported at ambient temperatures. The latter results in a reduction of storage and handling costs for the IAEA inspector, in comparison with the use of high resolution lithium-drifted Ge detectors. The MCA and the accessory equipment also performed reliably. It is concluded that, although the Davidson portable MCA performed reliably, a higher degree of portability and electronic versatility would be desirable to assist the IAEA inspector in the field. Equipment such as the compact MCA recently developed by Los Alamos National Laboratory and/or the B-SAM developed by Brookhaven National Laboratory do have these features and, as such, would be more useful to the IAEC during field measurements. These field tests, but prototypes are being tried and evaluated by the IAEA inspectorate. At this writing the first commercialunits are being marketed in the US.

Research Organization:
Oak Ridge Gaseous Diffusion Plant, TN (USA)
DOE Contract Number:
W-7405-ENG-26
OSTI ID:
5359331
Report Number(s):
K/OA-5206; ON: DE82012790; TRN: 82-013081
Country of Publication:
United States
Language:
English

Similar Records

UF/sub 6/ sample bottle assay meter
Technical Report · Sun Jan 01 00:00:00 EST 1984 · OSTI ID:5359331

Recent progress in the testing and implementation of measurement equipment for safeguards applications
Conference · Thu Jan 01 00:00:00 EST 1987 · Transactions of the American Nuclear Society; (USA) · OSTI ID:5359331

Feasibility of nondestructive assay measurements in uranium enrichment plants
Technical Report · Sat Apr 01 00:00:00 EST 1978 · OSTI ID:5359331