Heavy ion inelastic scattering with a 4. pi. gamma detector

Conference ·
OSTI ID:5353555
Heavy-ion inelastic scattering with a new technique that uses a 4{pi} {gamma}-ray detector in coincidence with charged particle detectors is applied to {sup 24}Mg(200 MeV) + {sup 208}Pb scattering. In addition to differential cross sections, a complete particle-{gamma} angular correlation is obtained for decay of the 2{sub 1}{sup +} (1.37 MeV) state of {sup 24}Mg. The data are analyzed in coupled-channels. The correlation data proves to be especially sensitive to the static quadrupole moment. 14 refs., 9 figs.