Descriptions of 1982 performance are provided for five flat plate and five concentrator photovoltaic systems. They range in size from 18 kW to 225 kW. All of the systems have extensive instrumentation; performance readings are generally available every 10 minutes. Flat plate systems are reliable, although not particularly efficient (5.6% to 8.1%). Well-tuned concentrator systems are more efficient (over 10%), but are subject to more mechanical problems. Insolation availability varies widely from day-to-day, even in the desert southwest. Average achievable capacity factors, based on insolation availability, vary by site over a range of 20% to 30%. Many of the sites operated within 80% to 90% of their achievable value.

Research Organization:
Boeing Computer Services Co., Tukwila, WA (USA). Energy Technology Applications Div.
OSTI ID:
5353423
Report Number(s):
EPRI-AP-3244; ON: DE84920079
Country of Publication:
United States
Language:
English