This report, prepared primarily for the BWR Owners Group summarizes status and capabilities for radiographic detection of crack-like flaws in BWR piping. Section 1 describes the status of MINAC, a portable radiographic source for inspection utilizing a linear accelerator as of May 1983. Section 2 describes the theory and practice of radiographic detection of intergranular stress corrosion cracks in BWR piping.