Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Thermometry in the multirod burst test program. [PWR; BWR]

Technical Report ·
OSTI ID:5344068

A temperature measurement error analysis was performed for the Type S (0.25-mm-diam, bare-wire) and Type K (0.71-mm-diam, sheathed) thermocouple circuits used to measure the temperature of the Zircaloy-clad, electrically heated fuel-rod simulators in the Multirod Burst Test program (MRBT) at Oak Ridge National Laboratory (ORNL). An important objective of the MRBT program is to improve the understanding of the behavior of the Zircaloy cladding of nuclear fuel rods under conditions postulated for a large-break, loss-of-coolant accident. Eight categories of error sources were studied both analytically and experimentally: thermal shunting; electrical shuntng and leakage; thermocouple calibration; thermocouple decalibration in service; thermoelectric properties of thermocouple extension wire, plugs, and jacks; thermocouple reference junction; data acquisition system; and electrical noise.

Research Organization:
Oak Ridge National Lab., TN (USA)
DOE Contract Number:
W-7405-ENG-26
OSTI ID:
5344068
Report Number(s):
NUREG/CR-2470; ORNL/TM-8024; ON: DE82014692
Country of Publication:
United States
Language:
English