Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Magnetic measurements of the correction and adjustment magnets of the main ring

Conference ·
OSTI ID:5326821
Correction magnets correct the field imperfections and alignment errors of the main quadrupole and bend magnets. For reducing and controlling chromaticity there are 186 sextupoles and 78 octupoles, while for suppressing various resonances there are 12 normal and 18 skew sextupoles and 24 normal and 19 skew quadrupoles. Beam positions are individually controlled by 108 horizontal and 108 skew dipoles. This report includes results of the all Main Ring correction and adjustment magnet harmonic measurements. The measurement principle and basic equations are described.
Research Organization:
Fermi National Accelerator Lab., Batavia, IL (USA)
DOE Contract Number:
AC02-76CH03000
OSTI ID:
5326821
Report Number(s):
FNAL-TM-1412; ON: DE86014466
Country of Publication:
United States
Language:
English

Similar Records

A New correction magnet package for the Fermilab Booster Synchrotron
Conference · Sun May 01 00:00:00 EDT 2005 · OSTI ID:15017099

Superconducting correction magnets for the HERA proton storage ring
Conference · Mon Feb 29 23:00:00 EST 1988 · IEEE Trans. Magn.; (United States) · OSTI ID:6221888

Booster Ring Correction Magnets
Technical Report · Fri May 20 00:00:00 EDT 1994 · OSTI ID:1150600