Solar Pilot Plant, Phase I. Preliminary design report. Volume III. Collector subsystem. CDRL item 2
The Honeywell collector subsystem features a low-profile, multifaceted heliostat designed to provide high reflectivity and accurate angular and spatial positioning of the redirected solar energy under all conditions of wind load and mirror attitude within the design operational envelope. The heliostats are arranged in a circular field around a cavity receiver on a tower halfway south of the field center. A calibration array mounted on the receiver tower provides capability to measure individual heliostat beam location and energy periodically. This information and weather data from the collector field are transmitted to a computerized control subsystem that addresses the individual heliostat to correct pointing errors and determine when the mirrors need cleaning. This volume contains a detailed subsystem design description, a presentation of the design process, and the results of the SRE heliostat test program.
- Research Organization:
- Honeywell, Inc., Minneapolis, MN (USA). Energy Resources Center
- Sponsoring Organization:
- USDOE
- OSTI ID:
- 5323292
- Report Number(s):
- SAN/1109-8/5
- Country of Publication:
- United States
- Language:
- English
Similar Records
Solar Pilot Plant Phase I, detailed design report: collector subsystem research experiment. CDRL Item No. 6 (Approved)
Central Receiver Solar Thermal Power System, Phase 1. CDRL Item 2. Pilot Plant preliminary design report. Volume III, Book 1. Collector subsystem
Related Subjects
140702* -- Solar Thermal Power Systems-- Central Receiver
CENTRAL RECEIVERS
CONTROL SYSTEMS
DESIGN
HELIOSTATS
MAINTENANCE
MECHANICAL STRUCTURES
OPERATION
OPTICAL PROPERTIES
PERFORMANCE TESTING
PHYSICAL PROPERTIES
POWER PLANTS
POWER RANGE 1-10 MW
REFLECTIVITY
SOLAR POWER PLANTS
SOLAR THERMAL POWER PLANTS
SPECIFICATIONS
SURFACE PROPERTIES
TESTING