Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Orifice-meter measurement errors caused by gas-system pulsations can be controlled

Journal Article · · Oil and Gas Journal; (USA)
OSTI ID:5321741
 [1]
  1. Arkla Energy Resources, Shreveport, LA (US)
Pulsation-induced inaccuracies in orifice meter gas-flow measurement can be eliminated or at least better controlled. In today's increasingly competitive gas-supply marketplace, such errors can no longer be ignored. In some instances, pulsations have caused errors of 30-50% in volumes. Policies and procedures of Arkla Energy Resources, Shreveport, La., reflect current efforts to combat the problem. Orifice-meter pulsation error can be divided into three categories: those associated with the primary element itself (across the flange taps); those in the gauge line/manifold/transducer system;; and those within the recording and analysis system. Each category is significant in that total meter error contains all three types (box). While it would be desirable to segregate the problems and solve them independently, it is very difficult to do. It becomes apparent quickly that all three occur in many cases. The focus of this discussion is on primary-element errors; if these are reduced, other errors tend to be minimal.
OSTI ID:
5321741
Journal Information:
Oil and Gas Journal; (USA), Journal Name: Oil and Gas Journal; (USA) Vol. 87:42; ISSN OIGJA; ISSN 0030-1388
Country of Publication:
United States
Language:
English